Konica Xpress CR
Dual bay CR system
World’s Fastest Dual-Bay CR System. Xpress CR, the latest break-through in CR technology, delivers unsurpassed total performance in workflow, image quality, and configurability.
No longer limited by the single-bay or multi-bay choice, you can customize your Xpress CR configuration to fit your specific clinical workflow, while meeting your throughput, redundancy and budgetary requirements. Designed with high reliability and easy serviceability in mind, Xpress CR is a major leap in CR technology.
Fast! 24 seconds to preview and 40 seconds cycle time
Dual Bay with input and output bays, and 6 seconds to insert the second plate
Configurable to process multiple plates simultaneously
Versatile: scan a plate at any reader for Workload Balancing
Compact footprint for space savingsSuperior image quality using the best Detector Quantum Efficiency (DQE) in plate technology
A new Compact, high-performance design Utilizing a unique dual bay design,the high speed reader of REGIUS Model 190 processes up to 90 plates per hour for maximum performance. This next generation reader radically improves workflow all within a mere 58×58 cm footprint. |
![]() |
Centralized image checking for flexible layout The "Ultimate Resource Sharing" concept provides the flexibility to separate the location of the consoles and the readers. This allows for the same fast and through image checking as with conventional systems. The result:system layout and productivity are optimized according to the number of examinations conduded, the work line and floor space. |
![]() |
2ch slot with independent insert / eject simplifies operation ln this uniquely innovative design, the entire cassette is loaded into the front slot and ejected out of the rear slot. This helps make the examination handling process exceptionally smooth and efficient. |
![]() |
43.75µm Read Function (option) ln addition to the 175 and 87.5µm read capability, REGIUS MODEL 190 is capable of supporting a new 43.75µm read function for mammography (outside US). This function is invaluable for producing diagnostic quality for mammography images, where recognition of subtle pathological changes is essential. Featuring a new cassette size to provide the ideal examination environment. ln addition to the world's first 11"×14" size featured in REGIUS MODEL170, the new line-up available on REGIUS MODEL 190 includes the 15×30cm size to provide even greater examination efficiency. |
|
| Exposure size | 14”×17”/14”×14”/11”×14”/10”×12”/8”×10”/ 18×24cm/24×30cm/15×30cm and others |
| Sampling Pitch | 3Types:87.5/175 and 43.75µm for Mammography |
| Maximum Resolution | 4020×4892 (14”×17”/87.5µm) 5440×6776 (24×30cm/43.75µm/Mammography) 7080×9480 (14”×17”/43.75µm/PCM) |
| Digital Gradation Level | 4096 levels (12bit) |
| Processing Capability | approx. 90plates/hour (14”×14”/175µm) |
| Cassette Feed/Load Time or Cassette Cycle Time | approx. 40 seconds (14”×14”/175µm) |
| Slots | Insert×1 (plus 1 stack) Eject×1 (4-stack) |
| Outer Dimensions/Weight | W580×D580×H1230mm/approx. 170kg |
| Power Consumption | AC100/115/120/200/220/230/240V ±10% 50/60Hz approx. 1.1kW |
| Operating Conditions | Temperature:15-30? Humidity:40-80%RH (no condensation) |

| One CS-3 unit seamlessly controls both reader units of the Model190 and Model 370. For superior processing continuity, the flow of exposures is uninterrupted while the images are acquired. | ![]() |
| Images are always displayed on the CS-3 where the plate is registered, regardless of which the reader unit used to scan the plate. This makes it easier for the operator to check image quality while maximizing the reader utilization. | |
| This tool allows the user to modify processing parameter settings, examination key layout, and other settings with ease. The operation is highly visually oriented:users can browse previous images while using slide bars to change the settings;images are then updated as the settings change. The drop and drag function for creating examination keys are also intuitive and simple to use. | |
| Image Processing | Automatic Gradation Processing (G Processing) Frequency Processing (F Processing) Equalization Processing (E Processing) Hybrid Processing (H Processing) |
| Image Output | Maximum Host:3ch for normal, 1ch for backup Printer:2ch for normal, 1ch for backup CS-3 Standard Software Host or Printer:1ch for normal, 1ch for backup |
| DICOM Support | Basic Grayscale Print Management (SCU) Storage (SCU) Modality Worklist Management Modality Performed Procedure Step Grayscale Standard Display Function (print output) |
| Maximum Connection | REGIUS 170/190 16units and REGIUS 370 1unit |
| Output Format | 1×1, 2×1, 1×2 |
| Main Options | Hardware option Bar Code Reader for Cassette Registration CS-1 PDA CS-1 PDA CRADLE IDS WW Software option CS-3 MWM/FTP/DETACHED Option CS-3 MPPS/DETACHED Option CS-3 HQ Mammography Option CS-3 DICOM Output Additional#1 CS-3 DICOM Output Additional#2 CS-3 DICOM Output Additional#3 CS-3 DICOM Output Additional#4 CS-3 DICOM Output Package CS-3 Stitching Option CS-3 Image Sharing Option CS-3 Data Analysis Option |