Konica Xpress CR

Dual bay CR system

World’s Fastest Dual-Bay CR System. Xpress CR, the latest break-through in CR technology, delivers unsurpassed total performance in workflow, image quality, and configurability.

No longer limited by the single-bay or multi-bay choice, you can customize your Xpress CR configuration to fit your specific clinical workflow, while meeting your throughput, redundancy and budgetary requirements. Designed with high reliability and easy serviceability in mind, Xpress CR is a major leap in CR technology.

Fast! 24 seconds to preview and 40 seconds cycle time

Dual Bay with input and output bays, and 6 seconds to insert the second plate

Configurable to process multiple plates simultaneously

Versatile: scan a plate at any reader for Workload Balancing

Compact footprint for space savingsSuperior image quality using the best Detector Quantum Efficiency (DQE) in plate technology

A new Compact, high-performance design

Utilizing a unique dual bay design,the high speed reader of REGIUS Model 190 processes up to 90 plates per hour for maximum performance. This next generation reader radically improves workflow all within a mere 58×58 cm footprint.

Centralized image checking for flexible layout

The "Ultimate Resource Sharing" concept provides the flexibility to separate the location of the consoles and the readers. This allows for the same fast and through image checking as with conventional systems. The result:system layout and productivity are optimized according to the number of examinations conduded, the work line and floor space.

2ch slot with independent insert / eject simplifies operation

ln this uniquely innovative design, the entire cassette is loaded into the front slot and ejected out of the rear slot. This helps make the examination handling process exceptionally smooth and efficient.

43.75µm Read Function (option)

ln addition to the 175 and 87.5µm read capability, REGIUS MODEL 190 is capable of supporting a new 43.75µm read function for mammography (outside US). This function is invaluable for producing diagnostic quality for mammography images, where recognition of subtle pathological changes is essential.

Featuring a new cassette size to provide the ideal examination environment.

ln addition to the world's first 11"×14" size featured in REGIUS MODEL170, the new line-up available on REGIUS MODEL 190 includes the 15×30cm size to provide even greater examination efficiency.

Exposure size 14”×17”/14”×14”/11”×14”/10”×12”/8”×10”/
18×24cm/24×30cm/15×30cm and others
Sampling Pitch 3Types:87.5/175 and 43.75µm for Mammography
Maximum Resolution 4020×4892 (14”×17”/87.5µm)
5440×6776 (24×30cm/43.75µm/Mammography)
7080×9480 (14”×17”/43.75µm/PCM)
Digital Gradation Level 4096 levels (12bit)
Processing Capability approx. 90plates/hour (14”×14”/175µm)
Cassette Feed/Load Time or Cassette Cycle Time approx. 40 seconds (14”×14”/175µm)
Slots Insert×1 (plus 1 stack)
Eject×1 (4-stack)
Outer Dimensions/Weight W580×D580×H1230mm/approx. 170kg
Power Consumption AC100/115/120/200/220/230/240V ±10%
50/60Hz approx. 1.1kW
Operating Conditions Temperature:15-30?
Humidity:40-80%RH (no condensation)

One CS-3 unit seamlessly controls both reader units of the Model190 and Model 370. For superior processing continuity, the flow of exposures is uninterrupted while the images are acquired.
Images are always displayed on the CS-3 where the plate is registered, regardless of which the reader unit used to scan the plate. This makes it easier for the operator to check image quality while maximizing the reader utilization.
This tool allows the user to modify processing parameter settings, examination key layout, and other settings with ease. The operation is highly visually oriented:users can browse previous images while using slide bars to change the settings;images are then updated as the settings change. The drop and drag function for creating examination keys are also intuitive and simple to use.
Image Processing Automatic Gradation Processing (G Processing)
Frequency Processing (F Processing)
Equalization Processing (E Processing)
Hybrid Processing (H Processing)
Image Output Maximum
Host:3ch for normal, 1ch for backup
Printer:2ch for normal, 1ch for backup
CS-3 Standard Software
Host or Printer:1ch for normal, 1ch for backup
DICOM Support Basic Grayscale Print Management (SCU)
Storage (SCU)
Modality Worklist Management
Modality Performed Procedure Step
Grayscale Standard Display Function (print output)
Maximum Connection REGIUS 170/190 16units and REGIUS 370 1unit
Output Format 1×1, 2×1, 1×2
Main Options Hardware option
Bar Code Reader for Cassette Registration
CS-1 PDA
CS-1 PDA CRADLE
IDS WW
Software option
CS-3 MWM/FTP/DETACHED Option
CS-3 MPPS/DETACHED Option
CS-3 HQ Mammography Option
CS-3 DICOM Output Additional#1
CS-3 DICOM Output Additional#2
CS-3 DICOM Output Additional#3
CS-3 DICOM Output Additional#4
CS-3 DICOM Output Package
CS-3 Stitching Option
CS-3 Image Sharing Option
CS-3 Data Analysis Option